NEW Voltage mA Calibrator Measurement and Source Functions 0.05% Accuracy 24V Loop Power Handheld Calibrator 06

$264.99

VICTOR 06 is a high-performance Voltage mA Calibrator designed for professionals who demand precision in both measurement and sourcing. It measures DCV from -110mV to 35V with up to 0.02% accuracy, and DCI from -35mA to 35mA at 0.02%+4µA accuracy. As a true Voltage mA Calibrator, it simultaneously sources 0-22mA DC current (active or passive) and 0-11V DC voltage with 0.05% accuracy. The built-in 24V loop power, percentage display, dual readouts, and automatic waveform output make this Voltage mA Calibrator an indispensable tool for field service and lab calibration.

 

 

 

 

 

 

Reviews

There are no reviews yet.

Be the first to review “NEW Voltage mA Calibrator Measurement and Source Functions 0.05% Accuracy 24V Loop Power Handheld Calibrator 06”

Your email address will not be published. Required fields are marked *

VICTOR 06 – The Precision Voltage MA Calibrator for Simultaneous Measure & Source

1. True Dual-Function Champion – Measure and Source at the Same Time

Most calibrators force you to choose between measuring and sourcing. The VICTOR 06 is different. As a professional Voltage MA Calibrator, it displays input measurement values and output set values simultaneously on screen. This Voltage MA Calibrator lets you watch how a transmitter responds while you actively drive the loop. Troubleshooting control valves, testing I/P converters, or verifying isolators becomes intuitive and fast.

2. Unmatched Measurement Accuracy – Up to 0.02% on 35V Range

Measurement matters. The VICTOR 06 measures DC voltage from -35.000V to 35.000V with 0.02%+2mV accuracy – that is lab grade. On the 100mV range, this Voltage MA Calibrator resolves down to 0.001mV (1µV), making it ideal for thermocouple simulation verification and low-level sensor testing. The 0.02%+4µA current measurement accuracy on ±35mA means you can trust every loop reading.

3. Precision Current Sourcing 0-22mA with Active or Passive Modes

The VICTOR 06 sources 0.000mA to 22.000mA DC current with 0.05%+4µA accuracy. But here is the real power: this Voltage MA Calibrator supports both active output (internal power) and passive output (simulate a 2-wire transmitter). Switch modes instantly. Test a PLC analog input with active mode, then simulate a transmitter in passive mode – all with the same Voltage MA Calibrator.

4. Voltage Sourcing from -1V to 11V at 0.05% Accuracy

Need a stable voltage source for chart recorders, VFD speed references, or controller analog outputs? The VICTOR 06 outputs DC voltage from -1.000V to 11.000V with 0.001V resolution and 0.05%+2mV accuracy. This Voltage MA Calibrator gives you negative voltage output as well – perfect for bipolar signal testing or simulating reverse-acting transducers.

5. Built-In 24V Loop Power Supply with Simultaneous Measurement

Stop carrying a separate loop power supply. The VICTOR 06 provides internal 24V circuit power (10% accuracy) while simultaneously measuring current. As a Voltage MA Calibrator, it powers your 2-wire transmitter and reads its output in one connection. No external batteries, no series resistors. Just connect, power, and measure.

6. 5-Digit Display with mA Percentage Mode

Clarity is king. The VICTOR 06 features a 5-digit display for both measurement and output. Switch the mA readout to percentage mode (0-100% for 4-20mA or 0-20mA). This Voltage MA Calibrator eliminates mental math – you see directly that 12mA equals 50%. Reduce errors, speed up valve stroke checks, and impress your QC auditor.

7. Manual Stepping and Automatic Waveform Output

The VICTOR 06 does not just sit there. When outputting DC current, this Voltage MA Calibrator provides manual step (increase/decrease by position) and automatic waveform output functions. Ramp up slowly to test valve sticking. Step through 4-8-12-16-20mA to check linearity. Send a slow triangle wave to simulate process drift. Automation saves hours of repetitive thumb-pressing.

8. Wide Voltage Measurement Ranges – From Microvolts to 35V

One Voltage MA Calibrator covers almost every industrial voltage need. Measure -110.000mV to 110.000mV with 0.001mV resolution – ideal for load cells and thermocouples. Switch to 1V range for 0.0001V resolution. Jump to 35V range for PLC outputs and power supplies. The VICTOR 06 adapts, not the other way around.

9. Fast 2-3 Measurements Per Second

Slow refresh rates hide transient problems. The VICTOR 06 updates measurements 2-3 times per second. This Voltage MA Calibrator catches flickering signals, loose connections, and noisy loops that slower tools miss. When you are chasing intermittent faults, every refresh matters.

10. True 5-Digit Resolution on Both Input and Output

Many so-called precision tools hide coarse internal resolution. The VICTOR 06 displays 5 digits for both measurement and output values. That means 0.001mA resolution on current and 0.001V on voltage. This Voltage MA Calibrator gives you the confidence to certify instruments to 0.1% of span without second-guessing your test equipment.

11. Loop Detection Function – Power and Read Simultaneously

The loop detection function is a game-changer. Activate the internal 24V supply while measuring current – this Voltage MA Calibrator becomes a complete loop tester. Connect to any 2-wire transmitter, and you instantly see the live mA reading. No external power supply, no shunt resistor, no complicated hookup diagrams.

12. Percentage Display for mA – Intuitive 4-20mA Testing

4-20mA is the universal process signal, but raw mA numbers require mental conversion. The VICTOR 06 displays mA directly as percent of range. This Voltage MA Calibrator shows 50% for 12mA, 75% for 16mA, 25% for 8mA. Train new technicians in minutes. Validate loop scaling without a calculator.

13. Active and Passive Output – One Tool, Two Personalities

Some jobs need a loop-powered simulator. Others need an active source. The VICTOR 06 gives you both. In active mode, this Voltage MA Calibrator internally powers the current loop. In passive (simulate) mode, it acts like a transmitter, drawing power from an external supply. Change modes with a button. Carry one Voltage MA Calibrator instead of two specialized tools.

14. Designed for Field Service and Calibration Labs

With ±35mA measurement range, the VICTOR 06 handles everything from 0-20mA to 4-20mA to 0-10V signals. The -110mV to 35V DCV measurement range covers thermocouples, RTD transmitters, pressure transducers, and level sensors. This Voltage MA Calibrator is equally at home on a factory floor, an offshore platform, or an NIST-traceable calibration bench.

15. Intuitive Operation – Manual Stepping by Position

No confusing menus. The VICTOR 06 allows manual increase or decrease of output settings by position. Turn a knob or press dedicated up/down controls – this Voltage MA Calibrator responds instantly. Need exactly 8.345mA? Step to it quickly. The tactile feedback means you keep your eyes on the device under test, not on the buttons.

16. Simultaneous Display of Input and Output – Closed-Loop Testing Made Easy

Here is the killer feature: the VICTOR 06 shows measured input and sourced output on the same screen. This Voltage MA Calibrator lets you perform closed-loop testing without switching display modes. Stimulate a pressure transmitter with 12mA (output) and watch the actual pressure reading (input measurement) in real time. Verify transfer functions instantly.

17. Built Tough for Industrial Environments

The VICTOR 06 is not a fragile lab toy. It is a rugged Voltage MA Calibrator built for daily use. With high-contrast display, clear terminal markings, and over-voltage protection on inputs, it survives tool bags, workbenches, and field conditions. Rely on it year after year.

If you calibrate, commission, or troubleshoot process instruments, the VICTOR 06 is the Voltage MA Calibrator you have been waiting for. It measures with 0.02% accuracy, sources with 0.05% accuracy, powers 24V loops, and displays everything simultaneously. Stop switching tools. Start using the VICTOR 06.

You may also like…